<LOGO>
FM Transmitter Measurement Report
Created: 2025-09-30 11-26-11
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 63 dBuV VOLTAGE
Pilot RDS Phase Difference
6.5 kHz 4.2 kHz -12 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 71 kHz 9800 29,8980
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
5,5 dBr 7,27 dBr 8,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 11:26, 30.09.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (64 dBuV) Max at: 71 kHz MIN: 11 kHz % above 75 kHz: 29,8980 Acquired: 2025/09/30 11:25:07 Total samples: 9800 Equivalent time: 0:08:10 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 8,0 dBr MIN: 5,5 dBr AVE: 7,27 dBr % above 10,2 dBr: 0,0 Last value: 8,0 dBr (2025/09/30 11:25:06) Station: 96.90 MHz, signal: 4/5 (64 dBuV) 11:18 11:19 11:20 11:21 11:22 11:23 11:24 11:25 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality